Data Centres & Telecom
Precision cooling with concurrent maintainability, free-cooling economisers and monitored power for server rooms, exchanges and towers.

Server halls and telecom exchanges need cooling that is available 99.99% of the time, holds 18–27 °C at the rack inlet and does not waste power moving air. MHM designs chilled-water and DX precision cooling with N+1 or 2N redundancy, hot-aisle containment, economisers for the cooler months and BMS/DCIM integration.
We also supply the generators, LT panels and UPS-room cooling that keep a site up through a grid failure, and maintain them under contracts with guaranteed response.
The engineering problems in data centres & telecom
Concurrent maintainability
N+1 chillers, dual pipe risers and CRAH units so any component can be serviced with the hall live.
PUE and part-load
High chilled-water temperatures, VFD everything and free-cooling in December–February.
Airflow management
Hot-aisle containment, raised-floor or in-row units and rack-inlet sensors on the BMS.
Power continuity
Generator sets, ATS and panel design that restart cooling within seconds of an outage.
How we solve them
- 1
Precision cooling
Chilled-water CRAH or DX CRAC units in N+1/2N with containment.
- 2
Central plant
Air-cooled chillers with buffer tanks for ride-through and economiser coils.
- 3
Power
Generators, LT panels, ATS and UPS-room cooling.
- 4
Monitoring & AMC
BMS/DCIM integration and Comprehensive AMC with 8-hour response.
Products specified for data centres & telecom
Electric Chillers
Air-cooled and water-cooled chillers from 10 to 850 TR, with genuine spares.
HVAC Systems
AHU, FCU, VRF and ducted-split systems for factories, hospitals and offices.
Pumps
End-suction, inline, split-case, booster and submersible pumps with VFD packages.
Building Management Systems
SIEMENS Desigo and KMC Conquest BACnet systems for plants and buildings.
Electrical Panels
LT/HT switchboards, distribution, PFI, motor control and VFD panels.
Generators
Diesel and gas gensets, 30–2000 kVA, with ATS and synchronising.
Fire Protection & Lifts
Fire pumps, hydrants, sprinklers, detection and lifts for factories.
Data Centres & Telecom plants running MHM equipment
Common questions from data centres & telecom plants
Below about 50 kW IT load, DX precision units with N+1 are simpler and cheaper. Above that, chilled water with buffer tanks gives better efficiency and ride-through.
Yes — BACnet/IP or Modbus TCP points for every chiller, CRAH, generator and panel are provided with the point list.
Industries we serve
Textile & Garments
Dyeing, finishing, spinning and garment plants: process chilled water for jet dyeing, humidification for spinning, comfort cooling for sewing floors.
Pharmaceuticals
GMP HVAC with validated temperature, humidity and pressure control, purified-water plants and documented maintenance for audit day.
Steel & Re-rolling
Induction-furnace and mill cooling: closed-loop soft-water circuits, high-capacity cooling towers, plate heat exchangers and pumps that run three shifts.
Food & Beverage
Hygienic process cooling, cold rooms and ice-water systems for edible oil, dairy, beverage, bakery, poultry and seafood plants.
Plastics & Packaging
Mould and extruder cooling, compressed air and clean power for injection moulding, PET, film, pipe and packaging plants.
Commercial Buildings
Central HVAC for malls, hotels, offices and showrooms: chillers, AHUs, VRF, BMS and fire systems that keep tenants comfortable and bills predictable.
Hospitals
Operating-theatre and ward HVAC with pressure control, redundancy and 24-hour support — because a hospital plant is never allowed to stop.
Government & Institutional
Public buildings, defence workshops and institutions: tendered HVAC and utility works delivered to PWD specifications with full documentation.
Planning a data centres & telecom plant or expansion?
Site survey, load calculation and a written proposal are free. We will show you a reference plant like yours.